Hits:Updated:2019-06-11 14:06:40【Print】
The mold temperature machine is composed of a water tank, a heating and cooling system, a power transmission system, a liquid level control system, a temperature sensor, an injection port and the like. Typically, the pump in the power transmission system causes the hot fluid to reach the mold from the tank with the built-in heater and cooler, and then return from the mold to the tank; the temperature sensor measures the temperature of the hot fluid and transmits the data to the control section. Controller; the controller regulates the temperature of the hot fluid to indirectly adjust the temperature of the mold. If the mold temperature is in production and the temperature of the mold exceeds the set value of the controller, the controller opens the solenoid valve to open the inlet pipe until the temperature of the hot liquid, that is, the temperature of the mold returns to the set value. If the mold temperature is lower than the set value, the controller turns on the heater. |